| Brand Name: | Deye |
| Model Number: | SUN-8K-G05-LV |
| MOQ: | 1 piece |
| Price: | $220-300 / piece |
Model | SUN-8K-G05-LV | |||||||
Input Side | ||||||||
Max. DC Input Power (kW) | 10.4 | |||||||
Max. DC Input Voltage (V) | 800 | |||||||
Start-up DC Input Voltage (V) | 250 | |||||||
MPPT Operating Range (V) | 200-700 | |||||||
Max. DC Input Current (A) | 13+26 | |||||||
Max. Short Circuit Current (A) | 19.5+39 | |||||||
No.of MPP Trackers | 2 | |||||||
No.of Strings per MPP Tracker | 1+2 | |||||||
Output Side | ||||||||
Rated Output Power (kW) | 8 | |||||||
Max. Active Power (kW) | 8 | |||||||
Rated Output Voltage/Range (V) | 3L/N/PE 120V/208V, 127V/220V, 133V/230V 0.85Un-1.1Un (this may vary with grid standards) | |||||||
Rated Grid Frequency (Hz) | 50/60 | |||||||
Operating Phase | Three Phase | |||||||
Rated AC Grid Output Current (A) | 22.3/21/20.1 | |||||||
Max. AC Output Current (A) | 22.3/21/20.1 | |||||||
Output Power Factor | 0.8 leading to 0.8 lagging | |||||||
Total Harmonics Current Distortion (THDi) | <3% | |||||||
DC Injection Current (mA) | <0.5% | |||||||
Efficiency | ||||||||
Max. Efficiency | 98.5% | |||||||
Euro Efficiency | 97.5% | |||||||
MPPT Efficiency | >99% | |||||||
Protection | ||||||||
DC Reverse-Polarity Protection | Yes | |||||||
AC Short Circuit Protection | Yes | |||||||
AC Output Overcurrent Protection | Yes | |||||||
Output Overvoltage Protection | Yes | |||||||
Insulation Resistance Protection | Yes | |||||||
Ground Fault Monitoring | Yes | |||||||
Anti-islanding Protection | Yes | |||||||
Temperature Protection | Yes | |||||||
Integrated DC Switch | Yes | |||||||
Remote Software upload | Yes | |||||||
Remote Change of Operating Parameters | Yes | |||||||
Surge Protection | DC Type II / AC Type II | |||||||
General Data | ||||||||
Cabinet Size (WxHxD mm) | 332×472×203 (Excluding Connectors and Brackets) | |||||||
Weight (kg) | 15 | |||||||
Topology | Transformerless | |||||||
Internal Consumption | <1W (Night) | |||||||
Running Temperature | -25-65℃, >45℃ Derating | |||||||
Ingress Protection | IP65 | |||||||
Noise Emission (Typical) | ≤40 dB | |||||||
Cooling Concept | Smart Cooling | |||||||
Permissible Altitude (m) | 4000 | |||||||
Warranty | 5 Years | |||||||
Grid Connection Standard | NBR 16149, NBR 16150, EN 50549, RD 140 | |||||||
Operating Surroundings Humidity | 0-100% | |||||||
Safety EMC / Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | |||||||
Features | ||||||||
Display | LCD1602 | |||||||
Interface | RS485/RS232/Wifi/LAN | |||||||