| Brand Name: | Growatt |
| Model Number: | MAX60KTL3LV |
| MOQ: | 1 piece |
| Price: | $1,860-1,900 / piece |
Datasheet | MAX50KTL3LV | MAX60KTL3LV | MAX70KTL3LV | MAX80KTL3LV | ||||
Input data(PV) | ||||||||
Max. recommended PV power (for module STC) | 75000W | 90000W | 105000W | 120000W | ||||
Max. DC voltage | 1100V | |||||||
Start voltage | 250V | |||||||
Nominal voltage | 585V | 585V | 600V | 600V | ||||
MPP voltage range | 200V-1000V | |||||||
No. of MPP trackers | 6 | 6 | 7 | 7 | ||||
No. of PV strings per MPP tracker | 2 | 1/1/2 | ||||||
Max. input current per MPP tracker | 26A | 13.5A/13.5A/27A | ||||||
Max. short-circuit current per MPP tracker | 32A | 16.9A/16.9A/33.8A | ||||||
Output data(AC) | ||||||||
AC nominal power | 50000W | 60000W | 70000W | 80000W | ||||
Max. AC apparent power | 55500VA | 66600VA | 77700VA | 88800VA | ||||
Nominal AC voltage(range*) | 220V/380V, 230V/400V (340-440V) | |||||||
AC grid frequency(range*) | 50/60 Hz (45-55Hz/55-65 Hz) | |||||||
Max. output current | 80.5A | 96.6A | 112.7A | 128.8A | ||||
Adjustable power factor | 0.8leading.…0.8lagging | |||||||
THD | <3% | |||||||
AC grid connection type | 3W+N+PE | |||||||
Efficiency | ||||||||
MAX.efficiency | 98.8% | 98.8% | 99% | 99% | ||||
European efficiency | 98.4% | 98.4% | 98.5% | 98.5% | ||||
MPPT efficiency | 99.9% | |||||||
Profecfion devices | ||||||||
DC switch | Yes | |||||||
DC reverse polarilty protection | Yes | |||||||
AC/DC surge protection | Type III / Type III | |||||||
Insulation resistance monitoring | Yes | |||||||
AC short-circuit protection | Yes | |||||||
Ground fauit monitoring | Yes | |||||||
Grid monitoring | Yes | |||||||
Anti-islanding protection | Yes | |||||||
Residual-current monitoring unit | Yes | |||||||
AFCI protection | Optional | |||||||
Seneral data | ||||||||
Dimensions (W/H/D) | 860/600/300mm | |||||||
Weigh | 82kg | 82kg | 86kg | 86kg | ||||
Operating temperature range | -25℃ …+60℃ | |||||||
Nighttime power consumption | < 1W | |||||||
Topolog | Transformerless | |||||||
Cooling | Smart air cooling | |||||||
Protection degree | IP65 | |||||||
Relative humidity | 0-100% | |||||||
Altitude | 4000m | |||||||
DC Connection | H4/MC4(Optional | |||||||
AC connection | Cable gland +OT terminal | |||||||
Display | OLED+LED/WIFI+APP | |||||||
Interfaces: RS485 / USB/Wi-Fi/GPRS/ RF/LAN | Yes/Yes/Optional/Optional/Optional /Optional | |||||||
Wananty:5 yeas/10 yeans | Yes/Optional | |||||||
CE , VDE0126, Greece, EN50438, EN50549-1, C10/C11, UTE C 15-712, IEC62116, IEC61727, IEC 60068, IEC 61683, CEI0-21,CEI 0-16, N4105, DRRG, G98/G99, G100, NRS 097-2-1, MEA , PEA , KSC8565 | ||||||||